The CHINT EnergiX-P40 Power Distribution Unit (PDU) ,which is the new solution for distributing power to Deta Center IT loading. It provides maximum protection against transient overvoltages and overcurrents, preventing power outages or service interruptions. EnergiX-P40 has IEC 61439 type test certification and IEC 60068 semic report. It features live-swappable outgoing circuits, a modular layout for improved hardware management, and a high capacity for multiple circuits. It also houses an intelligent monitoring system that allows users to remotely manage circuit electrical data, security, and maintenance.
Electrical Characteristics
Rated current (In) :400A/200A
Rated power capacity(Pn) :277kVA@400V/138kVA@400V
Rate voltage(Un) & (Ue) :230/400V±5%
Rated insulation voltage(Ui): 690 Vac
Uimp: 6kV
Icc :MCCB/MCB 50kA/15kA
Frequency :50/60Hz
Number of poles :3Ph+N+PE
Operating temperature :0℃ -40℃
Storage temperature :-25℃ ~+70℃
Display* :HMI
Power Monitoring System* :Conventional or Branch circuit monitoring as required
Mechanical Characteristics
H*W*D(mm) :2200*1100*600
Weight(Including device):450kg
Color :RAL 7021 mate
Degree of protection (Closed/open doors):IP 31/IP 20
Inside door type :Lexan window door
Cables entry/exit :Top
Maintain type :Front
Corrosion prevention :Sea salt spray test
Form :Form 2B
The CHINT EnergiX-P40 Power Distribution Unit (PDU) ,which is the new solution for distributing power to Deta Center IT loading. It provides maximum protection against transient overvoltages and overcurrents, preventing power outages or service interruptions. EnergiX-P40 has IEC 61439 type test certification and IEC 60068 semic report. It features live-swappable outgoing circuits, a modular layout for improved hardware management, and a high capacity for multiple circuits. It also houses an intelligent monitoring system that allows users to remotely manage circuit electrical data, security, and maintenance.
Electrical Characteristics
Rated current (In) :400A/200A
Rated power capacity(Pn) :277kVA@400V/138kVA@400V
Rate voltage(Un) & (Ue) :230/400V±5%
Rated insulation voltage(Ui): 690 Vac
Uimp: 6kV
Icc :MCCB/MCB 50kA/15kA
Frequency :50/60Hz
Number of poles :3Ph+N+PE
Operating temperature :0℃ -40℃
Storage temperature :-25℃ ~+70℃
Display* :HMI
Power Monitoring System* :Conventional or Branch circuit monitoring as required
Mechanical Characteristics
H*W*D(mm) :2200*1100*600
Weight(Including device):450kg
Color :RAL 7021 mate
Degree of protection (Closed/open doors):IP 31/IP 20
Inside door type :Lexan window door
Cables entry/exit :Top
Maintain type :Front
Corrosion prevention :Sea salt spray test
Form :Form 2B
Tel: 02-38642389
Fax: 02-38642139 ZHEJIANG ICP RECORD NO. 12033679
Copyright 2019 CHINT Group. All Rights Reserved